The four categories of fault code

Every modern condensing boiler fault falls into one of four buckets: ignition (no gas / no spark), flame (rectification failure), sensor (NTC / flow / return), or safety (overheat / pressure / flue).

Top UK fault codes and the spare to buy

  • Worcester EA229 — no flame after ignition. 90 % gas valve or ignition lead (part 87161424040).
  • Vaillant F75 — pump/pressure sensor. Fit low-water-pressure sensor 0020219476 first, pump 0020221215 if unchanged.
  • Baxi E133 — flame loss. Check condensate trap, then gas valve 720078201.
  • Ideal Logic L2 — ignition lock-out. Ignition lead 175593, electrode 175584.
  • Glow-worm F22 — low pressure. Auto air vent + expansion vessel 0020014173.

When it isn't the boiler

Repeated F22 / low pressure faults are almost never the PRV. It's a failed expansion vessel losing charge, or a leaking rad valve. Pump down, recharge the vessel to 1 bar, refill to 1.2 bar cold. If pressure climbs above 2.5 bar hot, the vessel is done.

Frequently asked questions

Can I clear a fault code by resetting?
A reset clears a soft lock-out. If the same code returns within one heat demand, it is a hardware fault and the spare must be replaced.