How to Replace the Pcb on a Alpha CD-32C (UK)
Step-by-step UK guide to replacing the printed circuit board on a Alpha CD-32C. Part numbers, torques, commissioning.
Alpha
The part
Replace the main control PCB — the most common cause of no-heat, no-DHW and intermittent lockouts on Alpha CD-32C.
Isolate safely
Isolate at the fused spur and lock off. Discharge any residual mains voltage before touching connectors.
Fit and commission
Photograph every plug and its position on the Alpha CD-32C PCB before unclipping — connector positions differ subtly across firmware revisions.
Recommission checklist
Refill the Alpha CD-32C to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- PCB part number location?
- On Alpha CD-32C the PCB label is on the top-right of the board, printed as an 1.03-series code. Match every digit.
- Do I need to re-parameterise?
- Yes — enter the correct boiler model code in the service menu after fitting so the ignition curve, fan speed and gas rate match.
- Do I need to notify the manufacturer?
- Only if the Alpha CD-32C is in warranty — Alpha require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares