UK trade guideBoiler Spares 5 min readUpdated 11 July 2026

How to Replace the Ntc Sensor on a Alpha E-Tec 28 (UK)

Step-by-step UK guide to replacing the flow / return / DHW thermistor on a Alpha E-Tec 28. Part numbers, torques, commissioning.

Alpha

The part

Replace an NTC thermistor on Alpha E-Tec 28 for wildly inaccurate flow temps or an F22/F75/L1 low-water fault.

Isolate safely

Each NTC on Alpha E-Tec 28 clips onto the copper flow pipe with a spring clip. Fit fresh heat-sink compound before refitting.

Fit and commission

Cross-check resistance with a multimeter — 10 kΩ at 25 °C for standard blue-body NTCs.

Recommission checklist

Refill the Alpha E-Tec 28 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Which colour?
Flow NTC is normally blue, return NTC red on Alpha E-Tec 28. Do not swap.
Wire polarity?
NTCs are non-polar — but keep leads clear of ignition HT leads.
Do I need to notify the manufacturer?
Only if the Alpha E-Tec 28 is in warranty — Alpha require log of any part swap for labour claims.
Shop the spares

Browse boiler spares14,820 live parts.

View Boiler Spares