UK trade guideShower Spares 4 min readUpdated 10 July 2026

How to Replace a Aqualisa Quartz Classic Cartridge (UK)

Fit a genuine 022801 cartridge in a Aqualisa Quartz Classic. UK isolation, service pattern and cold flush.

Aqualisa

Identify

The Aqualisa Quartz Classic uses the 022801 cartridge. Confirm from the label under the temperature knob before ordering.

Isolate

Turn off hot and cold supplies — usually 15 mm service valves either side of the valve, or the local isolators under the floor. Open the valve to drop pressure.

Fit

Remove the temperature knob (grub screw at 4 o'clock on most Aqualisa valves). Undo the retaining nut, withdraw the old cartridge. Grease O-rings with silicone grease, fit new cartridge, torque nut to 12 Nm.

Commission

Flush cold-only for 30 s to clear any grease. Set stop position — on TMV2 units, set to 41 °C at maximum.

Frequently asked questions

OEM or compatible?
Aqualisa thermostatic cartridges must be OEM to preserve the TMV2 approval on hotels, care homes and schools.
How often to replace?
Hard water: every 2–3 years. Soft water: 5+ years.
Shop the spares

Browse shower spares5,410 live parts.