UK trade guideBoiler Spares 5 min readUpdated 11 July 2026

How to Replace the Pcb on a Ariston E-Combi ONE 24 (UK)

Step-by-step UK guide to replacing the printed circuit board on a Ariston E-Combi ONE 24. Part numbers, torques, commissioning.

Ariston

The part

Replace the main control PCB — the most common cause of no-heat, no-DHW and intermittent lockouts on Ariston E-Combi ONE 24.

Isolate safely

Isolate at the fused spur and lock off. Discharge any residual mains voltage before touching connectors.

Fit and commission

Photograph every plug and its position on the Ariston E-Combi ONE 24 PCB before unclipping — connector positions differ subtly across firmware revisions.

Recommission checklist

Refill the Ariston E-Combi ONE 24 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

PCB part number location?
On Ariston E-Combi ONE 24 the PCB label is on the top-right of the board, printed as an 60002-series code. Match every digit.
Do I need to re-parameterise?
Yes — enter the correct boiler model code in the service menu after fitting so the ignition curve, fan speed and gas rate match.
Do I need to notify the manufacturer?
Only if the Ariston E-Combi ONE 24 is in warranty — Ariston require log of any part swap for labour claims.
Shop the spares

Browse boiler spares14,820 live parts.

View Boiler Spares