How to Replace the Dhw Heat Exchanger on a Baxi 600 Combi 30 (UK)
Step-by-step UK guide to replacing the plate heat exchanger (PHE) on a Baxi 600 Combi 30. Part numbers, torques, commissioning.
Baxi
The part
Fit a new plate HEX on Baxi 600 Combi 30 when DHW runs lukewarm but CH temperatures are correct — classic scaled plate symptom.
Isolate safely
Isolate mains cold and CH, remove the four Allen bolts and lift the plate HEX from the hydraulic block on Baxi 600 Combi 30.
Fit and commission
Fit new O-rings and grease with silicone; never re-use the old seals.
Recommission checklist
Refill the Baxi 600 Combi 30 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Descale or replace?
- Descale up to 15% flow loss; replace beyond. Sentinel R200 works but takes 4 hours.
- Plate count?
- Baxi 600 Combi 30 uses a 10-plate or 14-plate HEX depending on rating — cross-check the model suffix.
- Do I need to notify the manufacturer?
- Only if the Baxi 600 Combi 30 is in warranty — Baxi require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares