How to Replace the Ignition Electrode on a Baxi 800 Combi 36 (UK)
Step-by-step UK guide to replacing the spark / ionisation electrode on a Baxi 800 Combi 36. Part numbers, torques, commissioning.
Baxi
The part
Renew the ignition and flame-sense electrodes on Baxi 800 Combi 36 when you get F27 / EA / L2 flame-detection faults after a clean burn.
Isolate safely
Both electrodes on Baxi 800 Combi 36 use ceramic insulators — never re-use if chipped.
Fit and commission
Set the spark gap to 3.5–4.0 mm and the ionisation gap so the tip sits 4–5 mm above the burner surface.
Recommission checklist
Refill the Baxi 800 Combi 36 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Combined or separate?
- Baxi 800 Combi 36 runs a two-electrode kit — one spark, one sense. Fit both together to avoid a second call-back.
- How do I test ionisation current?
- In service mode read the µA value on Baxi 800 Combi 36. Below 4 µA at steady state means clean or replace.
- Do I need to notify the manufacturer?
- Only if the Baxi 800 Combi 36 is in warranty — Baxi require log of any part swap for labour claims.