How to Replace the Expansion Vessel on a Baxi Platinum Combi 40 (UK)

Step-by-step UK guide to replacing the internal 8L / 10L / 12L expansion vessel on a Baxi Platinum Combi 40. Part numbers, torques, commissioning.

Baxi

The part

Replace or top-up the internal expansion vessel on Baxi Platinum Combi 40 when the pressure gauge climbs above 2.5 bar on heat-up.

Isolate safely

Fully drain the system to zero bar, disconnect the Schrader valve and check pre-charge — should be 0.75 bar for Baxi Platinum Combi 40.

Fit and commission

If the pre-charge holds but the diaphragm is perished, fit a new OEM vessel or an external 12 L wall-mount vessel on the return.

Recommission checklist

Refill the Baxi Platinum Combi 40 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

External vessel size?
For a system up to 100 L water content, an external 12 L vessel supplements the internal one on Baxi Platinum Combi 40.
What pre-charge?
0.75 bar for a 2-storey property, 1.0 bar for 3-storey. Charge with the system fully drained.
Do I need to notify the manufacturer?
Only if the Baxi Platinum Combi 40 is in warranty — Baxi require log of any part swap for labour claims.