UK trade guideBoiler Spares 5 min readUpdated 9 July 2026

How to Replace a Boiler Condensate Trap (UK)

Fit a new condensate siphon trap on Worcester, Vaillant, Baxi and Ideal boilers. Cures E133/F28 recycling faults.

Worcester BoschVaillantBaxiIdeal

Why the trap fails

Modern condensing boilers produce 2 L/day of acidic condensate. The trap seals combustion gases from the drain. Sludge (calcium carbonate + carbon) blocks the siphon within 3–5 years.

OEM part numbers

  • Worcester Greenstar — 87161029130.
  • Vaillant ecoTEC — 0020155086.
  • Baxi 800 — 720072201.
  • Ideal Logic — 173950.

Clean vs replace

Descale with a kettle-desalter first. If the plastic is discoloured (brown-yellow), replace — the acid has weakened the shell.

Frequently asked questions

Can I run the boiler with the trap removed?
Absolutely not. CO can enter the property via the drain. Isolate until refitted.