UK trade guideBoiler Spares 8 min readUpdated 8 July 2026

How to Replace a Boiler Fan (UK, Gas Safe Guide)

Diagnose and replace a boiler fan on Worcester, Vaillant, Baxi, Ideal and Glow-worm combis. Fault code cross-references and OEM numbers.

Worcester BoschVaillantBaxiIdealGlow-worm

Confirm the fan is at fault

Common fan fault codes: Worcester EA229, Vaillant F29 with no ignition sequence audible, Baxi E133/E168, Ideal Logic L2, Glow-worm F1. Before condemning the fan, check the Hall sensor voltage (typically 5 V) between the yellow and black leads at the PCB connector during a heat demand.

OEM fan cross-references

Fans are the most-superseded spare on modern boilers because motor suppliers change every 2–3 years. Always order the latest number — the mounting flange and PWM signal profile are unchanged, but the bearing life is significantly better.

  • Worcester Greenstar i/Junior: 87161431020 (supersedes 87172043600).
  • Vaillant ecoTEC plus 24/28/32: 0020219547 (supersedes 0020039222, 0020051763).
  • Baxi 800 Combi 2: 720873101.
  • Ideal Logic Combi 24/30: 175596.
  • Glow-worm Ultimate3: 0020257021.

Fit and test

Replace the fan-to-heat-exchanger gasket every time — it hardens after one heat cycle and won't reseal. After refit, run the flue gas analysis check (CO/CO₂ ratio) as per Gas Safe TB 143 before signing off.

Frequently asked questions

Do I need to reset the PCB after a fan swap?
Worcester and Ideal auto-detect. Vaillant ecoTEC requires D.093 diagnostic code entry to re-pair the fan speed table.