UK trade guideShower Spares 4 min readUpdated 11 July 2026

How to Replace the Flow Cartridge on a Bristan Glorious Thermostatic (UK)

UK guide to swapping the flow cartridge in a Bristan Glorious Thermostatic shower valve. TMV2 compliance, part numbers, tools.

Bristan

The part

Fit a new flow-control cartridge on the Bristan Glorious Thermostatic to fix stiff or leaking on/off — usually a 1/4-turn ceramic disc.

Isolate

Close the built-in isolators on the Bristan Glorious Thermostatic valve body — accessed through the escutcheon plate.

Swap the flow cartridge

Some Bristan valves use handed cartridges (L/R). Match the flat on the spindle to the handle orientation before refitting.

Commission

Balance hot and cold to within 0.5 bar. Run the Bristan Glorious Thermostatic at max flow for 3 minutes.

Verify max outlet temperature stays below 46 °C per BS EN 1111 by shutting off cold and reading the outlet.

Frequently asked questions

Standard or reversed?
Standard Bristan cartridges close clockwise. Reverse handles will require the -R variant.
Any grease?
Silicone grease only — petroleum jelly attacks the EPDM seals.
OEM or aftermarket for Bristan?
For TMV2/TMV3 compliance always fit genuine Bristan cartridges. Aftermarket voids the Glorious Thermostatic approval.
Shop the spares

Browse shower spares5,410 live parts.