How to Replace a DAB Evosta 60-180 (UK)

Fit a DAB Evosta 60-180 pump on a UK heating or boosted DHW system. Face-to-face, orientation, bleed sequence.

DAB

The pump

DAB Evosta 60-180 — confirm 130 mm or 180 mm face-to-face, and whether your system is single-phase 230 V or low-voltage.

Isolate

Turn off the boiler and 230 V spur. Close both pump gate valves. Have a shallow tray ready — approx 500 mL will spill.

Fit

Undo the pump unions, transfer the power lead terminating L/N/E in the correct order into the DAB Evosta 60-180 terminal box. Orient the pump head so the shaft is horizontal. Open valves, bleed via the centre screw until water flows clear.

Set the DAB Evosta 60-180 to the correct speed or auto-adapt curve per the OEM installer sheet.

Frequently asked questions

Speed setting for Evosta 60-180?
Most modern UK homes: setting II on a fixed-speed DAB; auto-adapt on DAB A-rated pumps.
Do I need to power-flush after fitting?
Best practice — but at minimum add 500 mL Fernox F1 or Sentinel X100 and fit a magnetic filter.
Is the DAB Evosta 60-180 ErP compliant?
Yes — all current UK-sold A-rated pumps meet the ErP <180 W directive.