How to Replace the Gas Valve on a Ferroli Modena HE 30C (UK)
Step-by-step UK guide to replacing the modulating gas valve on a Ferroli Modena HE 30C. Part numbers, torques, commissioning.
The part
Change the modulating gas valve on Ferroli Modena HE 30C for hard ignition, F27 flame-lift or repeated flame loss faults.
Isolate safely
Cap the gas at the isolator, disconnect the multi-pin harness and undo the gas valve union. Fit a new fibre washer.
Fit and commission
Perform a full gas rate and combustion analysis after fitting the Ferroli Modena HE 30C valve — CO/CO2 ratio must fall inside the OEM window.
Recommission checklist
Refill the Ferroli Modena HE 30C to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Do I need to gas-tighten test?
- Yes — a soundness test and let-by test is mandatory before recommissioning.
- Which spanner size?
- Most Ferroli Modena HE 30C gas valve inlets are ½" BSP, 24 mm across flats; use two spanners to avoid rotating the manifold.
- Do I need to notify the manufacturer?
- Only if the Ferroli Modena HE 30C is in warranty — Ferroli require log of any part swap for labour claims.