How to Replace the Ignition Electrode on a Glow-worm Compact 24c (UK)
Step-by-step UK guide to replacing the spark / ionisation electrode on a Glow-worm Compact 24c. Part numbers, torques, commissioning.
Glow-worm
The part
Renew the ignition and flame-sense electrodes on Glow-worm Compact 24c when you get F27 / EA / L2 flame-detection faults after a clean burn.
Isolate safely
Both electrodes on Glow-worm Compact 24c use ceramic insulators — never re-use if chipped.
Fit and commission
Set the spark gap to 3.5–4.0 mm and the ionisation gap so the tip sits 4–5 mm above the burner surface.
Recommission checklist
Refill the Glow-worm Compact 24c to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Combined or separate?
- Glow-worm Compact 24c runs a two-electrode kit — one spark, one sense. Fit both together to avoid a second call-back.
- How do I test ionisation current?
- In service mode read the µA value on Glow-worm Compact 24c. Below 4 µA at steady state means clean or replace.
- Do I need to notify the manufacturer?
- Only if the Glow-worm Compact 24c is in warranty — Glow-worm require log of any part swap for labour claims.