How to Replace the Siphon Trap on a Ideal Logic Plus 24 (UK)
Step-by-step UK guide to replacing the condensate siphon on a Ideal Logic Plus 24. Part numbers, torques, commissioning.
Ideal
The part
Replace the condensate siphon on Ideal Logic Plus 24 for D5 / F1 pressure faults after a hard frost or heavy servicing schedule.
Isolate safely
Isolate, drop the case front. Undo the siphon quick-release clip on Ideal Logic Plus 24, tip out old fluid.
Fit and commission
Prime the new siphon with 250 mL clean water before refitting — dry siphons throw immediate flue-pressure faults.
Recommission checklist
Refill the Ideal Logic Plus 24 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Interval?
- Inspect annually at service; replace at 5-year mark or after any freeze event.
- Can I fit generic?
- No — use OEM only; the seal geometry on Ideal Logic Plus 24 varies between production years.
- Do I need to notify the manufacturer?
- Only if the Ideal Logic Plus 24 is in warranty — Ideal require log of any part swap for labour claims.