How to Replace the Pressure Relief Valve on a Ideal Logic Plus 35 (UK)
Step-by-step UK guide to replacing the 3-bar PRV on a Ideal Logic Plus 35. Part numbers, torques, commissioning.
Ideal
The part
Fit a new 3-bar PRV on Ideal Logic Plus 35 when water dribbles constantly from the outside discharge pipe.
Isolate safely
Drain below the PRV, unscrew the old valve and fit new PTFE tape (10 turns clockwise).
Fit and commission
On Ideal Logic Plus 35 the PRV sits on the hydraulic block — torque to 25 Nm to avoid cracking the plastic manifold.
Recommission checklist
Refill the Ideal Logic Plus 35 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Why does the new one still weep?
- Almost always the expansion vessel — check pre-charge first before condemning the PRV.
- Any WRAS approval?
- Only fit WRAS-approved 3-bar PRVs to keep Ideal Logic Plus 35 within its Gas Safe commissioning envelope.
- Do I need to notify the manufacturer?
- Only if the Ideal Logic Plus 35 is in warranty — Ideal require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares