Fit a new fascia display on Main Eco Compact 30 when the screen is blank, dim or the touch buttons no longer respond.
Isolate safely
The display board is separate from the main PCB on Main Eco Compact 30. It plugs in via a 6-way ribbon or JST connector.
Fit and commission
Handle by the edges — ESD damages the driver IC before you even fit it.
Recommission checklist
Refill the Main Eco Compact 30 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Do I re-enter installer settings?
- Yes — the display holds the language and clock; installer parameters live on the main PCB and persist.
- Is a firmware update needed?
- Only if the OEM display carries a newer part suffix (e.g. -02). Older firmware can throw comms faults with newer main PCBs.
- Do I need to notify the manufacturer?
- Only if the Main Eco Compact 30 is in warranty — Main require log of any part swap for labour claims.