How to Replace the Flow Cartridge on a Mira Fino BIV (UK)
UK guide to swapping the flow cartridge in a Mira Fino BIV shower valve. TMV2 compliance, part numbers, tools.
Mira
The part
Fit a new flow-control cartridge on the Mira Fino BIV to fix stiff or leaking on/off — usually a 1/4-turn ceramic disc.
Isolate
Close the built-in isolators on the Mira Fino BIV valve body — accessed through the escutcheon plate.
Swap the flow cartridge
Some Mira valves use handed cartridges (L/R). Match the flat on the spindle to the handle orientation before refitting.
Commission
Balance hot and cold to within 0.5 bar. Run the Mira Fino BIV at max flow for 3 minutes.
Verify max outlet temperature stays below 46 °C per BS EN 1111 by shutting off cold and reading the outlet.
Frequently asked questions
- Standard or reversed?
- Standard Mira cartridges close clockwise. Reverse handles will require the -R variant.
- Any grease?
- Silicone grease only — petroleum jelly attacks the EPDM seals.
- OEM or aftermarket for Mira?
- For TMV2/TMV3 compliance always fit genuine Mira cartridges. Aftermarket voids the Fino BIV approval.
Shop the spares
Browse shower spares — 5,410 live parts.
View Shower Spares