How to Replace the Ignition Electrode on a Potterton Promax 33 HE (UK)
Step-by-step UK guide to replacing the spark / ionisation electrode on a Potterton Promax 33 HE. Part numbers, torques, commissioning.
Potterton
The part
Renew the ignition and flame-sense electrodes on Potterton Promax 33 HE when you get F27 / EA / L2 flame-detection faults after a clean burn.
Isolate safely
Both electrodes on Potterton Promax 33 HE use ceramic insulators — never re-use if chipped.
Fit and commission
Set the spark gap to 3.5–4.0 mm and the ionisation gap so the tip sits 4–5 mm above the burner surface.
Recommission checklist
Refill the Potterton Promax 33 HE to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Combined or separate?
- Potterton Promax 33 HE runs a two-electrode kit — one spark, one sense. Fit both together to avoid a second call-back.
- How do I test ionisation current?
- In service mode read the µA value on Potterton Promax 33 HE. Below 4 µA at steady state means clean or replace.
- Do I need to notify the manufacturer?
- Only if the Potterton Promax 33 HE is in warranty — Potterton require log of any part swap for labour claims.