How to Replace the Auto Air Vent on a Ravenheat CSI Primary 85T (UK)
Step-by-step UK guide to replacing the brass automatic air vent on a Ravenheat CSI Primary 85T. Part numbers, torques, commissioning.
Ravenheat
The part
Fit a new AAV on Ravenheat CSI Primary 85T when the boiler airlocks on start-up or the pump makes gurgling noises after refilling.
Isolate safely
Isolate flow and return, unscrew the AAV from the top of the pump head or air separator on Ravenheat CSI Primary 85T.
Fit and commission
Loosen the AAV cap one full turn once refitted — a fully-closed cap defeats the float.
Recommission checklist
Refill the Ravenheat CSI Primary 85T to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Any special height?
- Fit the highest point of the Ravenheat CSI Primary 85T circuit — that is where entrained air collects.
- How often should I service?
- Annually — the float sticks with sludge in unfiltered systems.
- Do I need to notify the manufacturer?
- Only if the Ravenheat CSI Primary 85T is in warranty — Ravenheat require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares