How to Replace the Dhw Heat Exchanger on a Ravenheat CSI Primary 85T (UK)
Step-by-step UK guide to replacing the plate heat exchanger (PHE) on a Ravenheat CSI Primary 85T. Part numbers, torques, commissioning.
Ravenheat
The part
Fit a new plate HEX on Ravenheat CSI Primary 85T when DHW runs lukewarm but CH temperatures are correct — classic scaled plate symptom.
Isolate safely
Isolate mains cold and CH, remove the four Allen bolts and lift the plate HEX from the hydraulic block on Ravenheat CSI Primary 85T.
Fit and commission
Fit new O-rings and grease with silicone; never re-use the old seals.
Recommission checklist
Refill the Ravenheat CSI Primary 85T to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Descale or replace?
- Descale up to 15% flow loss; replace beyond. Sentinel R200 works but takes 4 hours.
- Plate count?
- Ravenheat CSI Primary 85T uses a 10-plate or 14-plate HEX depending on rating — cross-check the model suffix.
- Do I need to notify the manufacturer?
- Only if the Ravenheat CSI Primary 85T is in warranty — Ravenheat require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares