UK trade guideShower Spares 5 min readUpdated 9 July 2026

How to Replace a Shower Solenoid Valve (UK)

Fit a new solenoid on Mira Sport, Triton T80si and Aqualisa Quartz digital showers. Symptoms and OEM refs.

MiraTritonAqualisa

Diagnosis

No flow but heater working = solenoid stuck closed. Continuous flow with switch off = solenoid stuck open.

OEM part numbers

  • Mira Sport / Sport Max — 415.15.
  • Triton T80si — S22320051.
  • Aqualisa Quartz digital — 216505.

Fit

Isolate mains + power. Drain unit. Solenoid unclips from mount with a plug and 1/2" BSP fittings.

Frequently asked questions

Can I clean a stuck solenoid instead of replacing?
Sometimes — scale on the plunger. Soak in citric acid 30 min. But if the coil is open-circuit, replace.
Shop the spares

Browse shower spares5,410 live parts.