How to Replace the Flow Cartridge on a Triton Dene TMV3 Bar (UK)

UK guide to swapping the flow cartridge in a Triton Dene TMV3 Bar shower valve. TMV2 compliance, part numbers, tools.

Triton

The part

Fit a new flow-control cartridge on the Triton Dene TMV3 Bar to fix stiff or leaking on/off — usually a 1/4-turn ceramic disc.

Isolate

Close the built-in isolators on the Triton Dene TMV3 Bar valve body — accessed through the escutcheon plate.

Swap the flow cartridge

Some Triton valves use handed cartridges (L/R). Match the flat on the spindle to the handle orientation before refitting.

Commission

Balance hot and cold to within 0.5 bar. Run the Triton Dene TMV3 Bar at max flow for 3 minutes.

Verify max outlet temperature stays below 46 °C per BS EN 1111 by shutting off cold and reading the outlet.

Frequently asked questions

Standard or reversed?
Standard Triton cartridges close clockwise. Reverse handles will require the -R variant.
Any grease?
Silicone grease only — petroleum jelly attacks the EPDM seals.
OEM or aftermarket for Triton?
For TMV2/TMV3 compliance always fit genuine Triton cartridges. Aftermarket voids the Dene TMV3 Bar approval.