How to Replace the Flow Cartridge on a Triton T80Z Fast-Fit (UK)

UK guide to swapping the flow cartridge in a Triton T80Z Fast-Fit shower valve. TMV2 compliance, part numbers, tools.

Triton

The part

Fit a new flow-control cartridge on the Triton T80Z Fast-Fit to fix stiff or leaking on/off — usually a 1/4-turn ceramic disc.

Isolate

Close the built-in isolators on the Triton T80Z Fast-Fit valve body — accessed through the escutcheon plate.

Swap the flow cartridge

Some Triton valves use handed cartridges (L/R). Match the flat on the spindle to the handle orientation before refitting.

Commission

Balance hot and cold to within 0.5 bar. Run the Triton T80Z Fast-Fit at max flow for 3 minutes.

Verify max outlet temperature stays below 46 °C per BS EN 1111 by shutting off cold and reading the outlet.

Frequently asked questions

Standard or reversed?
Standard Triton cartridges close clockwise. Reverse handles will require the -R variant.
Any grease?
Silicone grease only — petroleum jelly attacks the EPDM seals.
OEM or aftermarket for Triton?
For TMV2/TMV3 compliance always fit genuine Triton cartridges. Aftermarket voids the T80Z Fast-Fit approval.
Shop the spares

Browse shower spares5,410 live parts.