How to Replace the Ntc Sensor on a Vaillant ecoTEC Plus 418 (UK)

Step-by-step UK guide to replacing the flow / return / DHW thermistor on a Vaillant ecoTEC Plus 418. Part numbers, torques, commissioning.

Vaillant

The part

Replace an NTC thermistor on Vaillant ecoTEC Plus 418 for wildly inaccurate flow temps or an F22/F75/L1 low-water fault.

Isolate safely

Each NTC on Vaillant ecoTEC Plus 418 clips onto the copper flow pipe with a spring clip. Fit fresh heat-sink compound before refitting.

Fit and commission

Cross-check resistance with a multimeter — 10 kΩ at 25 °C for standard blue-body NTCs.

Recommission checklist

Refill the Vaillant ecoTEC Plus 418 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Which colour?
Flow NTC is normally blue, return NTC red on Vaillant ecoTEC Plus 418. Do not swap.
Wire polarity?
NTCs are non-polar — but keep leads clear of ignition HT leads.
Do I need to notify the manufacturer?
Only if the Vaillant ecoTEC Plus 418 is in warranty — Vaillant require log of any part swap for labour claims.
Shop the spares

Browse boiler spares14,820 live parts.

View Boiler Spares