How to Replace the Condensate Trap on a Vaillant ecoTEC Pro 28 (UK)

Step-by-step UK guide to replacing the internal condensate trap on a Vaillant ecoTEC Pro 28. Part numbers, torques, commissioning.

Vaillant

The part

Renew the internal condensate trap on Vaillant ecoTEC Pro 28 when you get D5, F1 or E133 pressure-switch faults after a service.

Isolate safely

The trap on Vaillant ecoTEC Pro 28 snaps into the case bottom — flood with clean water before refitting to prime the U-bend.

Fit and commission

Check the external condensate pipe fall (2.5° minimum) at the same time to avoid a repeat freeze-up.

Recommission checklist

Refill the Vaillant ecoTEC Pro 28 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Can I clean the old one?
Rinse and refit if the trap body is undamaged, but always fit new seals.
22 mm external pipe rule?
Yes — post-2018 the run outside the wall must be 32 mm insulated per BS 6798.
Do I need to notify the manufacturer?
Only if the Vaillant ecoTEC Pro 28 is in warranty — Vaillant require log of any part swap for labour claims.