UK trade guideBoiler Spares 5 min readUpdated 11 July 2026

How to Replace the Primary Heat Exchanger on a Vaillant ecoTEC Pro 28 (UK)

Step-by-step UK guide to replacing the aluminium/stainless primary HEX on a Vaillant ecoTEC Pro 28. Part numbers, torques, commissioning.

Vaillant

The part

Replace the primary heat exchanger on Vaillant ecoTEC Pro 28 when you see combustion products blowing back, F62/L9 faults or sooting on the burner.

Isolate safely

Drain and cap all four connections on Vaillant ecoTEC Pro 28. The HEX weighs 12–18 kg — get a second pair of hands.

Fit and commission

Torque new HEX unions to the OEM figure (typically 40 Nm for cast, 28 Nm for stainless) and refit new burner and door gaskets.

Recommission checklist

Refill the Vaillant ecoTEC Pro 28 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Warranty implications?
A HEX swap on an in-warranty Vaillant ecoTEC Pro 28 must be logged with the manufacturer — otherwise the labour claim voids.
System clean first?
Mandatory — power-flush and fit a magnetic filter or the new HEX will block within two years.
Do I need to notify the manufacturer?
Only if the Vaillant ecoTEC Pro 28 is in warranty — Vaillant require log of any part swap for labour claims.
Shop the spares

Browse boiler spares14,820 live parts.

View Boiler Spares