How to Replace the Dhw Heat Exchanger on a Vokera Easi-Heat Plus 25C (UK)
Step-by-step UK guide to replacing the plate heat exchanger (PHE) on a Vokera Easi-Heat Plus 25C. Part numbers, torques, commissioning.
Vokera
The part
Fit a new plate HEX on Vokera Easi-Heat Plus 25C when DHW runs lukewarm but CH temperatures are correct — classic scaled plate symptom.
Isolate safely
Isolate mains cold and CH, remove the four Allen bolts and lift the plate HEX from the hydraulic block on Vokera Easi-Heat Plus 25C.
Fit and commission
Fit new O-rings and grease with silicone; never re-use the old seals.
Recommission checklist
Refill the Vokera Easi-Heat Plus 25C to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Descale or replace?
- Descale up to 15% flow loss; replace beyond. Sentinel R200 works but takes 4 hours.
- Plate count?
- Vokera Easi-Heat Plus 25C uses a 10-plate or 14-plate HEX depending on rating — cross-check the model suffix.
- Do I need to notify the manufacturer?
- Only if the Vokera Easi-Heat Plus 25C is in warranty — Vokera require log of any part swap for labour claims.
Shop the spares
Browse boiler spares — 14,820 live parts.
View Boiler Spares