How to Replace the Siphon Trap on a Vokera Easi-Heat Plus 25C (UK)
Step-by-step UK guide to replacing the condensate siphon on a Vokera Easi-Heat Plus 25C. Part numbers, torques, commissioning.
The part
Replace the condensate siphon on Vokera Easi-Heat Plus 25C for D5 / F1 pressure faults after a hard frost or heavy servicing schedule.
Isolate safely
Isolate, drop the case front. Undo the siphon quick-release clip on Vokera Easi-Heat Plus 25C, tip out old fluid.
Fit and commission
Prime the new siphon with 250 mL clean water before refitting — dry siphons throw immediate flue-pressure faults.
Recommission checklist
Refill the Vokera Easi-Heat Plus 25C to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Interval?
- Inspect annually at service; replace at 5-year mark or after any freeze event.
- Can I fit generic?
- No — use OEM only; the seal geometry on Vokera Easi-Heat Plus 25C varies between production years.
- Do I need to notify the manufacturer?
- Only if the Vokera Easi-Heat Plus 25C is in warranty — Vokera require log of any part swap for labour claims.
Browse boiler spares — 14,820 live parts.