How to Replace the Dhw Heat Exchanger on a Vokera Vision 30C (UK)

Step-by-step UK guide to replacing the plate heat exchanger (PHE) on a Vokera Vision 30C. Part numbers, torques, commissioning.

Vokera

The part

Fit a new plate HEX on Vokera Vision 30C when DHW runs lukewarm but CH temperatures are correct — classic scaled plate symptom.

Isolate safely

Isolate mains cold and CH, remove the four Allen bolts and lift the plate HEX from the hydraulic block on Vokera Vision 30C.

Fit and commission

Fit new O-rings and grease with silicone; never re-use the old seals.

Recommission checklist

Refill the Vokera Vision 30C to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Descale or replace?
Descale up to 15% flow loss; replace beyond. Sentinel R200 works but takes 4 hours.
Plate count?
Vokera Vision 30C uses a 10-plate or 14-plate HEX depending on rating — cross-check the model suffix.
Do I need to notify the manufacturer?
Only if the Vokera Vision 30C is in warranty — Vokera require log of any part swap for labour claims.