UK trade guideBoiler Spares 5 min readUpdated 11 July 2026

How to Replace the Diverter Valve on a Worcester Bosch Greenstar 40i (UK)

Step-by-step UK guide to replacing the 3-way diverter valve on a Worcester Bosch Greenstar 40i. Part numbers, torques, commissioning.

Worcester Bosch

The part

Replace the diverter valve on Worcester Bosch Greenstar 40i when hot water runs cold on demand or the boiler cycles between CH and DHW.

Isolate safely

Drain to below the diverter body via the CH drain-off. On Worcester Bosch Greenstar 40i the diverter is a cartridge design — pull the retaining clip and lift out.

Fit and commission

Fit new O-rings, silicone-grease the cartridge and align the actuator drive slot before refitting the motor.

Recommission checklist

Refill the Worcester Bosch Greenstar 40i to 1.2 bar cold. Bleed high-point radiators and the internal AAV.

Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.

Frequently asked questions

Actuator or cartridge only?
Diagnose first: manually push the actuator pin. If it moves freely, replace the actuator only; if the pin sticks, the cartridge is scaled.
Any special tools?
A brass spanner or the OEM diverter tool avoids cracking the plastic body on Worcester Bosch Greenstar 40i.
Do I need to notify the manufacturer?
Only if the Worcester Bosch Greenstar 40i is in warranty — Worcester Bosch require log of any part swap for labour claims.
Shop the spares

Browse boiler spares14,820 live parts.

View Boiler Spares