How to Replace the Pressure Sensor on a Worcester Bosch Greenstar 8000 Life 30 (UK)
Step-by-step UK guide to replacing the hydraulic pressure transducer on a Worcester Bosch Greenstar 8000 Life 30. Part numbers, torques, commissioning.
The part
Fit a new pressure transducer on Worcester Bosch Greenstar 8000 Life 30 when the display shows correct pressure at rest but locks out on heat-up.
Isolate safely
The transducer on Worcester Bosch Greenstar 8000 Life 30 threads or clips into the hydraulic block. Drop pressure to zero before removal.
Fit and commission
Refit with a new O-ring; over-tightening cracks the plastic body.
Recommission checklist
Refill the Worcester Bosch Greenstar 8000 Life 30 to 1.2 bar cold. Bleed high-point radiators and the internal AAV.
Run a full flue-gas analysis after 15 minutes. Log the reading against the OEM commissioning envelope in the Benchmark book.
Frequently asked questions
- Digital or analogue?
- Worcester Bosch Greenstar 8000 Life 30 runs a 5 V ratiometric transducer — the display board reads voltage directly.
- Calibration?
- None — the PCB self-references at 0 bar and 1.5 bar; recommission per OEM sheet.
- Do I need to notify the manufacturer?
- Only if the Worcester Bosch Greenstar 8000 Life 30 is in warranty — Worcester Bosch require log of any part swap for labour claims.
Browse boiler spares — 14,820 live parts.
View Boiler Spares