UK trade guideCylinder Spares 6 min readUpdated 9 July 2026

How to Service a Megaflo Cylinder (UK)

Annual service on a Heatrae Sadia Megaflo Eco Plus: expansion, ERV, PRV, immersion and anode check.

Megaflo

Service checklist

  • Test expansion vessel Schrader — recharge to 3.5 bar cold.
  • Verify ERV at 6 bar, PRV at 3 bar.
  • Inspect tundish for weep.
  • Test immersion element resistance (10.5 Ω for 3 kW).
  • Check thermostat cut-out.

Records

Complete the Megaflo service log inside the cylinder cover — required for warranty claims.

Frequently asked questions

Do Megaflos have a sacrificial anode?
Older units yes. Eco Plus is Duplex stainless — no anode required.